Which of the following loss is not considered while calculating the total head loss between the inlet well and D/s FSL?

Which of the following loss is not considered while calculating the total head loss between the inlet well and D/s FSL? Correct Answer Loss due to contraction of section

The head loss between the inlet well and the D/s FSL is given by adding the losses due to entry, exit, loss due to sudden enlargement and loss due to friction in the pipe. HL = 0.5 V22/2g (Entry loss) + (V2 – V3)2/2g (sudden enlargement loss) + fLV32/2gd (Friction loss) + V32/2g (Exit loss) Where, V2 = Velocity of entry in pipe, V3 = Velocity through the pipe, L = assumed pipe length, d = diameter of the pipe, f = Darcy’s coefficient of friction = 0.012 and g = acceleration due to gravity.

Related Questions

The following questions have three statements. Study the question and the statements and decide which of the statement(s) is/are necessary to answer the question. In how many hours tap B can fill the completely empty tank? Statement I: The inlet tap A and the outlet tap C working simultaneously takes 40 hours to fill the tank. Statement II: Efficiency of inlet tap B is equal to efficiency of outlet tap C or 62.5% of the efficiency of inlet tap A. Statement III: The outlet tap C can empty a half filled tank in 12 hours.