Ambient air at 20 degree Celsius flows past a flat plate with a sharp leading edge at 3 m/s. The plate is heated uniformly throughout its entire length and is maintained at a surface temperature of 40 degree Celsius. Calculate the thickness of the thermal boundary layer. Assume that transition occurs at a critical Reynolds number of 500000

Ambient air at 20 degree Celsius flows past a flat plate with a sharp leading edge at 3 m/s. The plate is heated uniformly throughout its entire length and is maintained at a surface temperature of 40 degree Celsius. Calculate the thickness of the thermal boundary layer. Assume that transition occurs at a critical Reynolds number of 500000 Correct Answer 19.23 mm

Thickness = 0.976 (Thickness of hydrodynamic boundary layer)/ (Pr) 1/3.