Compute the required recycled rate for the flotation thickener with recycle for the following information: A/S = 0.008 mL/mg p = 275 atm Temperature: 20 degree Celsius Air solubility: 18.7 mL/L Recycle steam pressure: 275 kPa Fraction of saturation: 0.5 Surface Loading rate: 8 L/m2/min Sludge flow rate: 400 m3/d

Compute the required recycled rate for the flotation thickener with recycle for the following information: A/S = 0.008 mL/mg p = 275 atm Temperature: 20 degree Celsius Air solubility: 18.7 mL/L Recycle steam pressure: 275 kPa Fraction of saturation: 0.5 Surface Loading rate: 8 L/m2/min Sludge flow rate: 400 m3/d Correct Answer 462 m3/d

P= P+101.35/101.35. p= 3.73 atm.The pressure is calculated by this formula A/S = 1.3 Sa (fP-1)R/Sa. Q. R = 462 m3/d.