Calculate the tank volume for the Moving bed bioreactor system for the following data. Flow: 800 m3/h. BOD: 300 mg/L Retention time: 6 hrs

Calculate the tank volume for the Moving bed bioreactor system for the following data. Flow: 800 m3/h. BOD: 300 mg/L Retention time: 6 hrs Correct Answer 4800 m3

In this case as the BOD level is not that high, hence the retention time considered is 6 hrs. Volume of tank= Flow x Retention time. Volume= 800 X 6= 4800m3.