Calculate the tank volume for the Moving bed bioreactor system for the following data. Flow: 500 m3/h. BOD: 500 mg/L Retention time: 8 hrs

Calculate the tank volume for the Moving bed bioreactor system for the following data. Flow: 500 m3/h. BOD: 500 mg/L Retention time: 8 hrs Correct Answer 4000 m3

In this case as the BOD level is high, the retention time considered is 8 hrs. Volume of tank= Flow x Retention time. Volume= 500 X 8= 4000m3.