What is the formula for obtaining the temperature value in degrees centigrade from the LM35 Temperature Sensor while using an ADC?

What is the formula for obtaining the temperature value in degrees centigrade from the LM35 Temperature Sensor while using an ADC? Correct Answer °C=ADC/10mV

The correct formula for converting the voltage reading taken from the ADC into the correct degrees centigrade value of the temperature surrounding the sensor is °C=ADC/10mV. This is because 10mV is the scale factor of the LM35 Temperature Sensor Module.

Related Questions

Statement (I): To use a sensor, we generally need to add signal conditioning circuitry, such as circuits which amplify and convert from analog to digital, to get the sensor signal in the right form, take account of any non-linearities, and calibrate it. Statement (II): A smart sensor is integrated with the required buffering and conditioning circuitry in a single element and provides functions beyond that of just a sensor.