If the ISA 100 × 65 × 8 is used for tension member, with 100 mm leg as the connected leg using a welded connection. What will be the shear lag width?
If the ISA 100 × 65 × 8 is used for tension member, with 100 mm leg as the connected leg using a welded connection. What will be the shear lag width? Correct Answer 65 mm
Concepts:
In case of welded connections, the shear lag distance is given as:
bs = Wo
Wo = Width of outstanding leg
In case of bolted connection, the shear lag distance is given as:
bs = Wc + G – t
Wc= width of connected leg
G is the gauge distance
t thickness of section.
Calculation:
Given: Welded connection with Wc = 100 mm; Wo = 65 and t = 8 mm.
So, the shear lag width is
bs = 65 mm