As per IS 1343, at the time of initial tensioning, the maximum tensile stress immediately behind the anchorages shall be limited to p percent of the ultimate tensile strength of the wire, wherein p is
As per IS 1343, at the time of initial tensioning, the maximum tensile stress immediately behind the anchorages shall be limited to p percent of the ultimate tensile strength of the wire, wherein p is Correct Answer 76
Explanation:
- As per CI. 18.5.1 of IS 1343 at the time of initial tensing, the maximum tensile stress immediately behind the anchorages shall not exceed 80% of the ultimate tensile strength of wire or bar or strand.
As per the given option, we should take 76% (for safer side)
Important Points
- Grade of concrete:
- M40 for pre-tensioned members
- M30 for post-tensioned members