What is the flow area in the following diagram? Inner Tube Diameter = 20mm Outer Tube Diameter = 40mm Fin width = 5mm

What is the flow area in the following diagram? Inner Tube Diameter = 20mm Outer Tube Diameter = 40mm Fin width = 5mm Correct Answer 742.5 sq mm

We have Total Area, A = π/4 (402 – 202) – 5×10×4 = 742.5 sq mm.

Related Questions

Consider we have a Double Pipe Heat Exchanger, with the inner tube of diameter 20mm (neglect thickness) and outer tube of diameter 30mm. We have two fluids A & B, we desire to have their flow rates as 15m3/s and 21m3/s respectively. Which fluid pass arrangement would be best suited for the HE?