Consider we have a Double Pipe Heat Exchanger, with the inner tube of Outer diameter 20mm (thickness 2mm) and outer tube of inner diameter 30mm. We have two fluids A & B, we desire to have their flow rates as 15Kg/s and 21Kg/s respectively. What is the value of Hydraulic diameter for the annulus tube?

Consider we have a Double Pipe Heat Exchanger, with the inner tube of Outer diameter 20mm (thickness 2mm) and outer tube of inner diameter 30mm. We have two fluids A & B, we desire to have their flow rates as 15Kg/s and 21Kg/s respectively. What is the value of Hydraulic diameter for the annulus tube? Correct Answer 10mm

The Hydraulic diameter for the annulus tube is De = Doi – Dio, which is De = 30-20 = 10mm.

Related Questions

Consider we have a Double Pipe Heat Exchanger, with the inner tube of diameter 20mm (neglect thickness) and outer tube of diameter 30mm. We have two fluids A & B, we desire to have their flow rates as 15m3/s and 21m3/s respectively. Which fluid pass arrangement would be best suited for the HE?
Consider we have a 1-2 Shell and Tube Heat Exchanger with tube diameter 20mm and shell diameter 55mm, we have two fluids A&B, A is supply water and B is distilled water, we desire to have their flow rates as 15m3/s and 21m3/s respectively. Which fluid pass arrangement would be best suited for the HE?