Calculate the amount of air required for the equalization tank with the following details Flow: 500 m3/h BOD load: 800 mg/L

Calculate the amount of air required for the equalization tank with the following details Flow: 500 m3/h BOD load: 800 mg/L Correct Answer 2000 m3/hr

Volume of tank = flow x retention time considered = 500 x 8 =4000 m3. The air requirement is 0.5 m3/hr/ m3 tank volume. Therefor the air requirement considered is 4000 x 0.5 = 2000 m3/hr.