Calculate the volume of the aeration tank required for the following data: Flow: 800 m3/d BOD: 1000 mg/L F/M ratio: 0.15(extended aeration) MLSS : 3500 mg/L

Calculate the volume of the aeration tank required for the following data: Flow: 800 m3/d BOD: 1000 mg/L F/M ratio: 0.15(extended aeration) MLSS : 3500 mg/L Correct Answer High sludge volume index

Readily biodegradable COD if it is high in the influent, then the sludge volume index will be very high. Also this high level of COD would contribute to the floc formation. This also results in higher oxygen demand.