When instrument is at P the staff readings on P is 2.748 and on Q is 1.824 when instrument at Q the staff readings on P is 1.606and Q is 0.928. Distance between P and Q is 1010 mts. R.L. of P is 126.386. Find combined effect correction for curvature and refraction?
When instrument is at P the staff readings on P is 2.748 and on Q is 1.824 when instrument at Q the staff readings on P is 1.606and Q is 0.928. Distance between P and Q is 1010 mts. R.L. of P is 126.386. Find combined effect correction for curvature and refraction? Correct Answer 0.069 m
Combined correction for curvature and refraction is 0.06728 d2 = 0.06728(1.010)2 = 0.069 m.
মোঃ আরিফুল ইসলাম
Feb 20, 2025