Standard USBR stilling basin-II is useful for energy dissipation at the bottom of the overflow structure, if the approaching Froude number is ________________

Standard USBR stilling basin-II is useful for energy dissipation at the bottom of the overflow structure, if the approaching Froude number is ________________ Correct Answer more than 4.5

USBR has standardized stilling basins for different Froude numbers. USBR stilling basin- II is recommended for large structures when the Froude number is more than 4.5. The dissipation of energy will be 45 to 85%.