For a four pole, 16 slot armature with two coil-side/slot having wave connected progressive winding has single turn coils has simplex winding. The number of current paths is?
For a four pole, 16 slot armature with two coil-side/slot having wave connected progressive winding has single turn coils has simplex winding. The number of current paths is? Correct Answer 2
The number of parallel path for a wave wound machine is equal to two.