If a transmission line of zₒ=50Ω is matched using λ/4 transmission line of z₁=100Ω, then the transmission co efficient T₂ is:

If a transmission line of zₒ=50Ω is matched using λ/4 transmission line of z₁=100Ω, then the transmission co efficient T₂ is: Correct Answer 0.6667

When a transmission line is matched to a load by using a λ/4 transmission line, the transmission co-efficient T2 of the line is obtained using the expression 2Z0/ (Z1+Z0). Here Z1 is the characteristic impedance of the λ/4 transmission line and Z0 is the characteristic impedance of the transmission line. Substituting the given values, we get T2=0.6667.