PD controller is used to compensate system. Compared to the uncompensated system, the compensated system has:
PD controller is used to compensate system. Compared to the uncompensated system, the compensated system has: Correct Answer Higher noise amplification
The compensated system of the proportional derivative controller has bandwidth increases and signal to noise ratio decreases. This implies higher noise amplification in a compensated system using a PD controller.