1 Answers
Option 2 : Class C commutation
Class C commutation:
- There are mainly two techniques for thyristor commutation: Natural and Forced.
- The Forced commutation technique is further divided into five categories which are Class A, B, C, D, and E.
- Class A: Self or Load Commutation
- Class B: Resonant-Pulse Commutation
- Class C: Complementary Commutation
- Class D: Impulse Commutation
- Class E: External Pulse Commutation