1 Answers
Option 2 : 2 and 3 only
Interpoles:
The interpoles are the auxiliary poles, which are placed between the main poles. The interpoles are fitted to the yoke and are known as commutating poles. The use of the interpoles helps in reducing the reactance voltage and nullifies the cross magnetization effect of armature reaction, which results in a reduction in sparking at the commutator.
Armature resistance and field current:
For s shunt generator,
Terminal voltage Vt = Eg – IaRa and Ia = IL + If
Ia is armature current
Ra is armature resistance
If is the field current
IL is the line current
With an increase in armature resistance (Ra), the voltage drop IaRa increases.
With the reduction in field current, the armature current increases, and hence the voltage drop IaRa increases.