For a fluid flowing in an annulus space, the wetted perimeter for heat transfer and pressure drop are?
Same
Different
Never different
Linearly related
LohaHridoy
0
Edit
4
views
2025-01-04 04:42
1
Answers
AhmedNazir
Answer: Option 2
0
Thanks
4
views
Answered
2022-09-01 13:21
Report
Edit
Call
Related Questions
A heat exchanger with heat transfer surface area A and overall heat transfer coefficient U handles two fluids of heat capacities Cmax and Cmin. The number of transfer units (NTU) used in the analysis of heat exchanger is specified as?
1 Answers
7
Views
A cube at high temperature is immersed in a constant temperature bath. It loses heat from its top, bottom and side surfaces with heat transfer coefficients of h₁, h₂ and h₃ respectively. The average heat transfer coefficient for the cube is?
1 Answers
32
Views
Two fluids are flowing through two similar pipes of the same diameter. The Reynold's number is same. For the same flow rate if the viscosity of a fluid is reduced to half the value of the first fluid, the pressure drop will?
1 Answers
12
Views
The pressure drop per unit length of pipe incurred by a fluid 'X' flowing through pipe is Δp. If another fluid 'Y' having both the specific gravity & density just double of that of fluid 'X', flows through the same pipe at the same flow rate/average velocity, then the pressure drop in this case will be?
1 Answers
5
Views
A fluid is flowing inside the inner tube of a double pipe heat exchanger with diameter 'd'. For a fixed mass flow rate, the tube side heat transfer co-efficient for turbulent flow conditions is proportional to?
1 Answers
14
Views
For a laminar flow of fluid in a circular tube, 'h₁' is the convective heat transfer co-efficient at velocity 'V₁'. If the velocity is reduced by half and assuming the fluid properties are constant, the new convective heat transfer co-efficient is?
1 Answers
8
Views
If average heat transfer co-efficient is ha and the local coefficient at the end of the plate is hl then in case of heat transfer to a fluid flowing over a flat plate, heated over its entire length?
1 Answers
5
Views
The average heat transfer co-efficient over the entire length of the plate (ha) and the local heat transfer co-efficient (hL), in case of heat transfer over a flat plate in lminar zone is related as?
1 Answers
5
Views
Extended heat transfer surface like fins are used to increase the heat transfer rate. Fin efficiency is defined as the ratio of heat transferred across the fin surface to the theoretical heat transfer across an equal area held at the?
1 Answers
5
Views
In a double pipe (concentric) heat exchanger, the hydraulic radius for heat transfer (for a fluid flowing through the annulus) would be?
1 Answers
6
Views
কোরআন
হাদিস
চাকুরি প্রস্তুতি
বিশ্ববিদ্যালয় ভর্তি
মেডিকেল SBA
12
এইচএসসি
10
এসএসসি
8
জেএসসি
এক্সাম দিয়ে মেধা যাচাই করুন
Job Preparation (1125)
Admission (754)
এসএসসি (10)
এইচএসসি (5)
Login Required
You need to log in to continue.
Login
Cancel
Download Required
You need to download the app to make a call.
Download
Cancel