If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then?
the stator current will be zero
the stator current will be very small
the stator current will be very high
the back e.m.f. will be more than the supply voltage
LohaHridoy
0
Edit
4
views
2025-01-04 04:42
1
Answers
AhmedNazir
Answer: Option 1
0
Thanks
4
views
Answered
2022-09-01 13:21
Report
Edit
Call
Related Questions
A synchronous motor is running on a load with normal excitation. Now if the load on the motor is increased?
1 Answers
7
Views
If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to?
1 Answers
9
Views
If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from constant voltage supply its field excitation is increased, its power factor?
1 Answers
5
Views
If in a synchronous motor, driving mechanical load and drawing current at lagging power factor from constant voltage supply, its field excitation is increased, then its power factor?
1 Answers
5
Views
A synchronous motor running with normal excitation adjusts to load increases essentially by increase in?
1 Answers
5
Views
The effect of increasing the load on a synchronous motor running with normal excitation is to?
1 Answers
5
Views
A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the synchronous motor will?
1 Answers
9
Views
As the load is applied to a synchronous motor, the motor takes more armature current because?
1 Answers
5
Views
In a pre-stressed beam carrying an external load W with a bent tendon is having angle of inclination and pre-stressed load P. The net downward load at the centre is?
1 Answers
5
Views
In testing a pile by load test, pile platform is loaded with one and half times the design load and a maximum settlement is noted. The load is gradually removed and the consequent rebound is measured. For a safe pile, the net settlement (i.e. total settlement minus rebound) per tonne of test load should not exceed?
1 Answers
5
Views
কোরআন
হাদিস
চাকুরি প্রস্তুতি
বিশ্ববিদ্যালয় ভর্তি
মেডিকেল SBA
12
এইচএসসি
10
এসএসসি
8
জেএসসি
এক্সাম দিয়ে মেধা যাচাই করুন
Job Preparation (1125)
Admission (754)
এসএসসি (10)
এইচএসসি (5)
Login Required
You need to log in to continue.
Login
Cancel
Download Required
You need to download the app to make a call.
Download
Cancel