When water is sprayed on air, passing through an insulated chamber maintained at a temperature higher than the dew point of entering air but lower than its dry bulb temperature, then the air is?
Cooled and dehumified
Heated and humidified
Cooled and humidified
Heated and dehumidified
LohaHridoy
0
Edit
5
views
2025-01-04 04:42
1
Answers
AhmedNazir
Answer: Option 3
Let'
0
Thanks
5
views
Answered
2022-09-01 13:21
Report
Edit
Call
Related Questions
When the air is passed through an insulated chamber having sprays of water maintained at a temperature higher than the dew point temperature of entering air but lower than its dry bulb temperature, then the air is said to be?
1 Answers
7
Views
The ratio of the actual mass of water vapour in a unit mass of dry air to the mass of water vapour in the same mass of dry air when it is saturated at the same temperature and pressure, is called?
1 Answers
5
Views
Dry bulb temperature is the temperature of air recorded by a thermometer, when?
1 Answers
5
Views
When dry bulb temperature & wet bulb temperature of moist air is the same, it means that the?
1 Answers
6
Views
The heat transfer by conduction through a thick cylinder (Q) is given by (where T₁ = Higher temperature, T₂ = Lower temperature, r₁ = Inside radius, r₂ = Outside radius, l = Length of cylinder, and k = Thermal conductivity)?
1 Answers
5
Views
The bypass factor (B. P. F.) in case of sensible heating of air is (Where td₁ = Dry bulb temperature of air entering the heating coil, td₂ = Dry bulb temperature of air leaving the heating coil, and td₃ = Dry bulb temperature of heating coil)?
1 Answers
5
Views
Relative humidity is given by (where pv = Partial pressure of water vapour, pb = Barometric pressure, ps = Pressure of saturated air, pd = Pressure at dry bulb temperature, pw = Saturation pressure corresponding to wet bulb temperature, and μ = Degree of saturation)?
1 Answers
5
Views
The bypass factor, in case of sensible cooling of air, is given by (where td₁ = Dry bulb temperature of air entering the cooling coil, td₂ = Dry bulb temperature of air leaving the cooling coil, and td₃ = Dry bulb temperature of the cooling coil)?
1 Answers
5
Views
In case of dry spinning of polymers, the polymer solution in a volatile solvent is forced through the spinnerates into a warm air chamber, where the solvent evaporates leaving behind the polymer in the filament form. Dry spinning is used for __________ fibres.?
1 Answers
5
Views
If the solubilities of different components (in a liquid-liquid extraction system) increase with rise in temperature, then the temperature above which they dissolve completely is known as the critical solution temperature (CST or consolute temperature). If solubilities increase with decrease in temperature, then CST is the temperature below which they dissolve completely. If a binary system has no critical solution temperature, it implies that?
1 Answers
6
Views
কোরআন
হাদিস
চাকুরি প্রস্তুতি
বিশ্ববিদ্যালয় ভর্তি
মেডিকেল SBA
12
এইচএসসি
10
এসএসসি
8
জেএসসি
এক্সাম দিয়ে মেধা যাচাই করুন
Job Preparation (1125)
Admission (754)
এসএসসি (10)
এইচএসসি (5)
Login Required
You need to log in to continue.
Login
Cancel
Download Required
You need to download the app to make a call.
Download
Cancel