The rotor power input of 3-phase induction motor is 15 kW at a slip of 5%. The mechanical power developed at the shaft is?
The rotor power input of 3-phase induction motor is 15 kW at a slip of 5%. The mechanical power developed at the shaft is? Correct Answer 14.25 kW
Pm = (1-s)Pin = 0.95*15 = 14.25 kW.