In the design of Kettle reboiler given by Kern for isothermal boiling, it is assumed that the degree of sub-cooling and super-heating of the cold fluid is ___________

In the design of Kettle reboiler given by Kern for isothermal boiling, it is assumed that the degree of sub-cooling and super-heating of the cold fluid is ___________ Correct Answer Negligible

The Kern method of designing reboilers considers only the saturated steam operation regime and not the super/sub-heated steam as it involves the calculation of heat gain and loss of the steam besides its latent heat of vaporisation.