An electric wire of 1.25 mm diameter and 250 mm long is laid horizontally and submerged in water at 7 bar. The wire has an applied voltage of 2.2 V and carries a current of 130 amperes. If the surface of the wire is maintained at 200 degree Celsius, make calculations for the heat flux

An electric wire of 1.25 mm diameter and 250 mm long is laid horizontally and submerged in water at 7 bar. The wire has an applied voltage of 2.2 V and carries a current of 130 amperes. If the surface of the wire is maintained at 200 degree Celsius, make calculations for the heat flux Correct Answer 0.2915 * 10 6 W/m2

Q= V I = 286 W and A = 9.81 * 10 -4 m2. Therefore heat flux = Q/A.