Read the following statement about boilers. I. Water tube boiler is capable of generating steam of pressure more than 50 kg/cm2 . II. Fire tube boiler is suitable for generating steam of pressure less than 17.5 kg/cm2 . III. Water tube boiler occupy comparatively less space.
Read the following statement about boilers. I. Water tube boiler is capable of generating steam of pressure more than 50 kg/cm2 . II. Fire tube boiler is suitable for generating steam of pressure less than 17.5 kg/cm2 . III. Water tube boiler occupy comparatively less space. Correct Answer Statement I, II and III are true
In fire tube boiler water and steam are in same shell so higher pressure is not possible. In water tube boiler comparison to fire tube boiler, the drum do not contain any tabular heating surface so they can be built in smaller diameter and consequently they will withstand higher pressure.