The SOAs provided by the manufacturers are for
The SOAs provided by the manufacturers are for Correct Answer single pulse operation & a particular temperature
The manufacturer specifies the SOAs only for single pulse DC operation & a particular temperature (usually 20Degree Centigrade Scale). For actual operations, The SOA’s have to be modified using the thermal impedance charts.