Using the frequency scaling technique, convert 10kHz cut-off frequency of the low pass filter to a cutoff frequency of 16kHz.(Take C=0.01µF and R=15.9kΩ)

Using the frequency scaling technique, convert 10kHz cut-off frequency of the low pass filter to a cutoff frequency of 16kHz.(Take C=0.01µF and R=15.9kΩ) Correct Answer 9.94kΩ

To change a cut-off frequency from 10kHz to 16kHz,multiply 15.9kΩ resistor. =10kHz/16kHz =0.625. ∴ R =0.625×15.9kΩ =9.94kΩ. However 9.94kΩ is not a standard value. So, a potentiometer of 10kΩ is taken and adjusted to 9.94kΩ.

Related Questions

The low-pass active filter shown in the figure has a cut-off frequency of 2 kHz and a pass band gain of 1.5. The values of the resistors are
Electronics mcq question image
Find the gain and phase angle of the second order low pass filter? Where pass band gain of the filter is 5, frequency and the high cut-off frequency of the filter are 3000Hz and 1kHz.