Consider the following statements for a PI compensator for control system. 1. It is equivalent to adding a zero at origin 2. It reduces overshoot 3. It improves the steady state error of the system Which of the statements given above are correct?
Consider the following statements for a PI compensator for control system. 1. It is equivalent to adding a zero at origin 2. It reduces overshoot 3. It improves the steady state error of the system Which of the statements given above are correct? Correct Answer 2 and 3
PI(PROPORTIONAL INTEGRAL) compensator adds one open loop pole at origin and open loop zero at negative real axis. So it improves steady state error and reduces overshoot of the system .