Two joined graded index fibers that are perfectly aligned have refractive indices αR = 1.93 for receiving fiber αE = 2.15 for emitting fiber. Calculate the coupling loss.

Two joined graded index fibers that are perfectly aligned have refractive indices αR = 1.93 for receiving fiber αE = 2.15 for emitting fiber. Calculate the coupling loss. Correct Answer 0.23 dB

Coupling loss for two joined and perfectly aligned graded index fiber is given by LF(α) = -10log10αR(αE+2)/αE(αR+2) Where LF(α) = Coupling loss αR = refractive index of receiving fiber αE = refractive index of emitting fiber.