1. Increase in horse power rating
  2. Decrease in load angle
  3. Increase in flux density
  4. Decrease in flux density
4 views

1 Answers

Option 3 : Increase in flux density

We know that, ϕ = BA

Where ϕ is the flux

B is flux density

A is the cross-sectional area

For the constant flux, B is inversely proportional to A.

So, by increasing flux density the area of the motor will get reduce and hence the size of the motor will get reduce.