Which of the following methods of analysis of water distribution system is most suitable for long and narrow pipe system?
Circle method
Equivalent pipe method
Hardy cross method
Electrical analysis method
LohaHridoy
0
Edit
5
views
2025-01-04 04:42
1
Answers
AhmedNazir
Answer: Option 2
Let'
0
Thanks
5
views
Answered
2022-09-01 13:21
Report
Edit
Call
Related Questions
Which of the following two quantities when same, makes one pipe system equivalent to another pipe system?
1 Answers
4
Views
The diameter of the nozzle (d) for maximum transmission of power is given by (where D = Diameter of pipe, f = Darcy’s coefficient of friction for pipe, and l = Length of pipe)?
1 Answers
4
Views
According to Darcy's formula, the loss of head due to friction in the pipe is (where f = Darcy's coefficient, l = Length of pipe, v = Velocity of liquid in pipe, and d = Diameter of pipe)?
1 Answers
4
Views
The loss of head due to viscosity for laminar flow in pipes is (where d = Diameter of pipe, l = Length of pipe, v = Velocity of the liquid in the pipe, μ = Viscosity of the liquid, and w = Specific weight of the flowing liquid)?
1 Answers
5
Views
The type of valve which is provided to control the flow of water in the distribution system at street corners and where the pipe lines intersect is?
1 Answers
5
Views
The pressure drop per unit length for laminar flow of fluid through a long pipe is proportional to (where, A = cross-sectional area of the pipe & D = Diameter of the pipe)?
1 Answers
4
Views
Direction : Two statements I and II are given. These statement may be either independent causes or may be effects of independent causes or a common cause. One of these statements may be the effect of the other statements. Read both the statements and decide which of the following answer choice correctly depicts the relationship between these two statements. Mark answer : I. There is increase in water level of all the water tanks supplying drinking water to the city during the last fortnight. II. Most of the trains were cancelled last week due to water-logging on the tracks.?
1 Answers
5
Views
The method of analysis of distribution system in which the domestic supply is neglected and fire demand is considered is?
1 Answers
4
Views
The most economical lighting layout which is suitable for narrow roads is?
1 Answers
5
Views
The needle beam method of tunnelling (i) Is suitable for soils in which roof can stand for few minutes without support (ii) Is suitable for brick lining (iii) Is suitable for concrete lining (iv) Requires large number of trench jacks?
1 Answers
5
Views
কোরআন
হাদিস
চাকুরি প্রস্তুতি
বিশ্ববিদ্যালয় ভর্তি
মেডিকেল SBA
12
এইচএসসি
10
এসএসসি
8
জেএসসি
এক্সাম দিয়ে মেধা যাচাই করুন
Job Preparation (1125)
Admission (754)
এসএসসি (10)
এইচএসসি (5)
Login Required
You need to log in to continue.
Login
Cancel
Download Required
You need to download the app to make a call.
Download
Cancel