To increase the absorption factor, (where, G = gas flow rate, S = solvent flow rate)?
Increase both 'G' and 'S'
Decrease both 'G' and 'S'
Increase 'S' and decrease 'G'
Increase 'G' and decrease 'S'
LohaHridoy
0
Edit
4
views
2025-01-04 04:42
1
Answers
AhmedNazir
Answer: Option 3
Let'
0
Thanks
4
views
Answered
2022-09-01 13:21
Report
Edit
Call
Related Questions
Absorption factor method is used to calculate the number of ideal stages, when?
1 Answers
8
Views
Fourier's law of heat conduction is (where Q = Amount of heat flow through the body in unit time, A = Surface area of heat flow, taken at right angles to the direction of heat flow, dT = Temperature difference on the two faces of the body, dx = Thickness of the body, through which the heat flows, taken along the direction of heat flow, and k = Thermal conductivity of the body)?
1 Answers
4
Views
The compressibility factor of a gas is given by (where, V₁ = actual volume of the gas V₂ = gas volume predicted by ideal gas law )?
1 Answers
5
Views
Effectiveness factor (E) of a catalyst pellet is defined as, E = (actual rate within pore of catalyst/rate if notsnowed by pore diffusion) Effectiveness factor for a first order reaction is given by (where, T = Thiele modulus)?
1 Answers
5
Views
Absorption factor is defined as (where, S₁ = slope of the operating line S₂ = slope of the equilibrium curve)?
1 Answers
6
Views
The absorption factor is defined as (where, L = liquid flow rate, G = gas flow rate and, m = slope of the equilibrium line)?
1 Answers
4
Views
In case of dry spinning of polymers, the polymer solution in a volatile solvent is forced through the spinnerates into a warm air chamber, where the solvent evaporates leaving behind the polymer in the filament form. Dry spinning is used for __________ fibres.?
1 Answers
5
Views
In case of unsteady fluid flow, conditions & flow pattern change with the passage of time at a position in a flow situation. Which of the following is an example of unsteady flow?
1 Answers
5
Views
LMTD correction factor which is to be applied for a cross-flow heat exchanger increases with increase in the number of shell passes. Its value for a single pass cross flow heat exchanger is?
1 Answers
6
Views
Which of the following is an undesirable characteristic for the solvent used in gas absorption?
1 Answers
4
Views
কোরআন
হাদিস
চাকুরি প্রস্তুতি
বিশ্ববিদ্যালয় ভর্তি
মেডিকেল SBA
12
এইচএসসি
10
এসএসসি
8
জেএসসি
এক্সাম দিয়ে মেধা যাচাই করুন
Job Preparation (1125)
Admission (754)
এসএসসি (10)
এইচএসসি (5)
Login Required
You need to log in to continue.
Login
Cancel
Download Required
You need to download the app to make a call.
Download
Cancel