If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to

If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to Correct Answer increase in both armature current and power factor angle

Related Questions

A synchronous motor connected to infinite bus-bars has at constant full load, 100% excitation and unity power factor. On changing the excitation only, the armature current will have
A synchronous motor is running on a load with normal excitation. Now if the load on the motor is increased
A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn by it increases because