If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to

A increase in both armature current and power factor angle
B increase in back e.m.f. but decrease in armature current
C increase in both armature current and power factor which is lagging
D increase in torque angle but decrease in back e.m.f.

Correct Answer: increase in both armature current and power factor angle

Related Questions

A synchronous motor is running on a load with normal excitation. Now if the load on the motor is increased
A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn by it increases because
The effect of increasing the load on a synchronous motor running with normal excitation is to
As the load is applied to a synchronous motor, the motor takes more armature current because