What is the effect of demagnetizing component of armature reaction?
What is the effect of demagnetizing component of armature reaction? Correct Answer Reduces generator emf
When the armature of a dc machine carries current, the distributed armature winding produces its own mmf (distributed) known as armature reaction. The demagnetizing component acts in the opposite direction, reducing flux/pole in a machine, which will ultimately reduce generator emf.