A three phase induction motor is sometimes called a generalized transformer in so far as voltage and frequency transformation has been concerned. How a three phase induction motor operates when rotor frequency is greater than stator frequency?

A three phase induction motor is sometimes called a generalized transformer in so far as voltage and frequency transformation has been concerned. How a three phase induction motor operates when rotor frequency is greater than stator frequency? Correct Answer Rotor will be driven against rmf

As the rotor rotates at larger speed than the stator, the rmf speed is less than the rotor speed and it tries to rotate in the opposite direction to rmf.