The armature winding of a 2-pole, 3-phase alternator for each phase is distributed in a number of slots per phase. The RMS value of the voltage per phase is less than the RMS value of the voltage per coil multiplied by the number of coils in series because the _________

The armature winding of a 2-pole, 3-phase alternator for each phase is distributed in a number of slots per phase. The RMS value of the voltage per phase is less than the RMS value of the voltage per coil multiplied by the number of coils in series because the _________ Correct Answer equal RMS voltages in different coils of the phase has mutual phase difference

The phase displacement will be given by slot angular pitch γ.

Related Questions

A uniformly distributed winding on the stator has three full pitched coils, each coil having N turns and each turn carrying a current i. The MMF produced by the winding is?